Cart

Your cart is empty.

Add part numbers from the catalogue, or type any part number in the cart, even one that is not listed here.

Browse products
    Request a quotationView cart

    No prices online and no payment here. Our sales team replies by email with price and lead time.

    Choosing MLCC Alternates: Watch the DC Bias

    Two MLCCs with the same value, voltage and dielectric can give very different capacitance in a circuit. Why DC bias matters when you approve alternates.

    MLCC alternates: check capacitance at real voltage

    Share

    The MLCC shortage has pushed many engineering teams to approve alternates quickly: a different maker, a different case size, sometimes a different voltage rating. On paper the specifications match: same capacitance, same tolerance, same dielectric code. In the circuit, the result can be very different. The reason is DC bias, and it is the most common trap when replacing class II ceramic capacitors.

    What DC bias does

    Class II MLCCs, such as X7R, X5R and Y5V, use dielectrics based on barium titanate with very high permittivity. That is what allows large capacitance in a small case. But the permittivity of these materials falls when a DC voltage is applied, and the stronger the electric field in the dielectric, the larger the drop.

    Since the field depends on voltage divided by layer thickness, parts with thin dielectric layers suffer most. Those are exactly the parts most in demand: high capacitance in a small case at a low rated voltage. Such a capacitor, operated near its rated voltage, can deliver well under half of its nominal value.

    Class I dielectrics, such as C0G (NP0), behave differently. Their capacitance is essentially stable with voltage and temperature, but they are available only in much lower values.

    The temperature code does not include bias

    The EIA code describes how capacitance changes with temperature with no DC voltage applied. X7R means a change of no more than ±15% from -55 °C to +125 °C; X5R the same ±15% up to +85 °C; Y5V allows +22% to -82% from -30 °C to +85 °C. The DC bias loss comes on top of this, and on top of tolerance and ageing. Class II capacitors also lose capacitance slowly over time, a process that is reset when the part is heated above its Curie temperature, for example during soldering.

    Capacitance of class II parts also depends on the AC test voltage, so bench measurements must follow the maker’s test conditions. Read them as carefully as any other condition in a datasheet.

    Comparing MLCC alternates under DC bias

    Table comparing five ways to change an MLCC, such as a smaller case, a higher voltage rating, another maker, X5R for X7R and C0G for X7R, with the effect on capacitance under DC bias and what to check for each
    The same nominal capacitance can mean very different effective capacitance, depending on case size, rating, maker and dielectric.
    • Smaller case, same value and voltage. Usually thinner layers, so more loss under bias. A move from 0805 to 0603 can cut effective capacitance noticeably even though the nominal specification is the same.
    • Higher voltage rating. Often gives more effective capacitance at the same applied voltage, because the layers are thicker. But not always: some makers use the same dielectric thickness across several ratings, and a higher-rated part may be thicker. Check the curve and the part height, not the label.
    • Different maker, same specification. Materials and layer design differ, and so do bias curves. Two parts with identical datasheet headlines can differ widely at your operating voltage.
    • X5R for X7R. The bias behaviour is similar, but the upper temperature limit drops from 125 °C to 85 °C. Check the hottest point on the board, not just the ambient.
    • C0G for X7R. Removes the bias problem where the value is small enough to exist in C0G, typically in filters, timing and resonant circuits.

    Most large MLCC makers publish DC bias and temperature curves for each part number, and many offer online tools that calculate capacitance at a chosen voltage and temperature. Ask for these curves as part of every alternate approval.

    Where it matters most

    • Regulator outputs. DC-DC converters and LDOs depend on output capacitance for stability and transient response. Too little effective capacitance can cause ringing or oscillation. Check the regulator datasheet for the minimum effective capacitance it needs, and see our notes on DC-DC converter modules.
    • Converter inputs, where ripple current and DC voltage are both at their highest.
    • Hold-up, snubber and timing circuits, where performance depends directly on the capacitance value.

    Where bias losses make class II parts hard to use, a tantalum or polymer capacitor may be an alternative, with its own rules on voltage derating and ESR.

    A simple approval routine

    1. Record the real DC and ripple voltage at each capacitor position.
    2. Get the maker’s bias curve for the original part and for each alternate.
    3. Compare effective capacitance at operating voltage and at the highest board temperature.
    4. Confirm the minimum the circuit needs, with margin for tolerance and ageing.
    5. Test the first boards at the highest operating voltage, full load and high temperature: output ripple, transient response and start-up.

    Buyers can help by passing engineering the full part number of each proposed alternate, not just the value and case size, so that the right curves can be found.

    How Strade can help

    Strade’s engineers can propose MLCC alternates that match capacitance, voltage, dielectric and case size, and look at the makers’ DC bias data with your team before you approve. We supply passive components, semiconductors, connectors and power products to factories in Vietnam and across Asia, and inspect every lot on receipt.

    Send us the MLCC lines you need to replace, with the operating voltage at each position if you have it.

    Back to all news

    Services

    How Strade can help

    Request a quote for your part list

    Send the part numbers and quantities you need and our sales team will prepare a quotation.

      Excel, CSV or PDF, up to 2 MB.

      Download the Excel template